Alle kabler

  • AICI

    Optical cable for industrial environments. The cable is suitable for both indoor and outdoor installation. The outer sheath is made from black UV-stabilized and weather resistant material which is SHF1 classified, and may be exposed for shorter periods to fluids such as diesel and mineral oils. The resistance to these…

  • AICI MUD

    Optical cable for industrial environments. The cable is suitable for both indoor and outdoor installation. Continiuous submergence in water is not recommended. Outer sheath (1) is made from black UV-stabilized and weather resistant material and may be exposed for shorter periods to fluids such as diesel and mineral oils. The…

  • ATNL MV 750 10kV – Mellomspenningskabel

    Installasjon i tunneler med inntil 11 kV driftsspenning, hvor den elektriske funksjonsevnen skal opprettholdes under brann. Spesielt designet brannbestandig MV kabel. Kabelen har beskyttelse mot UV-stråling/sollys og har ekstra beskyttelse mot oljer og diesel. Halogenfri kabel anbefales brukt når det er viktig å unngå dannelse av tett røyk og korrosive…

  • Armoured PEL-tube

  • ARSIC-1

    Kabel for instrumentering og prosessstyring, overføring av digitale og lavnivå analoge signaler. PE som lederisolasjon, individuell folieskjerm av parene med jordlisse. Kabelen har også felles folieskjerm med jordlisse. Skjermene er isolert fra hverandre. Kabelen gir meget god beskyttelse mot elektromagnetisk støy. Parfargekode rød/blå med nummermerking. Ytterkappe av PVC. Konstruksjonen er…

  • ATN 1000

    Installasjon i tunneler med inntil 1 kV driftsspenning, hvor den elektriske funksjonsevnen skal opprettholdes under brann. Spesielt designet til ventilasjonssystemer. Kabelen har beskyttelse mot UV-stråling/sollys og har ekstra beskyttelse mot oljer og diesel. Halogenfri kabel anbefales brukt når det er viktig å unngå dannelse av tett røyk og korrosive gasser…

  • ATNL 1000 1kV – Ventilasjon

    Installasjon i tunneler med inntil 1 kV driftsspenning, hvor den elektriske funksjonsevnen skal opprettholdes under brann. Spesielt designet til ventilasjonssystemer. Cu-skjermen er 100% tett, har lav koblingsimpedans og oppfyller EMC-direktivet. Kabelen har beskyttelse mot UVstråling/sollys og har ekstra beskyttelse mot oljer og diesel. Halogenfri kabel anbefales brukt når det er…

  • AXAI-I/O-W

    Utendørs og innendørs Halogenfri og flammehemmende Fast kledning 2 – 24 fiber Langsgående vanntett

  • AXLJ-RMF-KOMBI 6/10(12) kV

    AXLJ-RMF-KOMBI er en trelederkabel for oppheng i stolper. AXLJ-RMF-KOMBI er konstruert for normal spennlengde 70 meter dog max 90 meter. Kabelen kan selvfølgelig også forlegges i jord

  • AXLJ-RMF-KOMBI 12/20(24) kV

    AXLJ-RMF-KOMBI är en trelederkabel for oppheng i stolper. AXLJ-RMF-KOMBI er konstruert for normal spennlengde 70 meter dog max 90 meter. Kabelen kan selvfølgelig også forlegges i jord

  • AXXI-I/O-W

    Utendørs/Innendørs Halogenfri og flammehemmende Fast kledning 4 - 24 fiber Langsgående vanntett

  • BendBrightXS Hvit 3,7mm

  • BendBrightXS Hvit 4,5mm

    ES9 fast kledning, 1 – 4 BendBright® XS fibre, aramidgarn, FireRes® ytterkappe(LSHF-FR). Kabelen er hvit, uten merketekst, for synlig installasjon innvendig og utvendig mot grensesnittboks.

  • BFOU 0.6-1(1.2)kV P5-P12

    Fixed installation for power, control and lighting in both EX (Zone 0, 1 & 2)- and safe areas, emergency and critical systems where requirement for fire resistance exists. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009.

  • BFOU 0.6-1(1.2)kV P5-P12 – Arctic Grade

    Fixed installation for power, control and lighting in both EX (Zone 0, 1 & 2)- and safe areas, emergency and critical systems where requirement for fire resistance exists. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the OIL & MUD resistance requirement in NEK 606. Meets the…

  • BFOU-HCF 0.6-1(1.2)kV P34 – Hydrocarbon Fire

    Fixed installation for power, control and lightning in both EX- and safe areas, emergency and critical systems where requirement for fire resistance is vital.

  • BFOU-HCF (c) 250V S16 – Hydrocarbon Fire

    Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for hydrocarbon fire resistance is vital.

  • BFOU-HCF (i) 250V S15 – Hydrocarbon Fire

    Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for hydrocarbon fire resistance is vital.

  • BFOU-JF 0.6-1kV – Jet Fire

    Fixed installation for power, control and lightning in both EX- and safe areas, emergency and critical systems where requirement for fire resistance is vital.

  • BFOU-VFD 0.6-1(1.8-3)kV – Class 2 – Variable Frequency Drives

    Special cable for Variable Frequency Drives / Azimuth motors. Suitable for voltage peaks up to 3000V. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009.

  • BFOU-VFD 0.6-1(1.8-3)kV – Class 5 – Variable Frequency Drives

    Special cable for Variable Frequency Drives / Azimuth motors up to 1kV. Suitable for voltage peaks up to 3600V. Armoured cable for fixed installations in ships and offshore units. Can be installed and operated both indoors and outdoors. Oil and MUD resistant to NEK606.

  • BFOU-XFR(c) 150-250(300)V – Extended Fire Resistant

    Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in NEK TS 606:2009. Cables have extended fire resistant (XFR) properties to IEC 60331-1&2 including water spray according to EN…

  • BFOU-XFR(i) 150-250(300)V – Extended Fire Resistant

    Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in NEK TS 606:2009. Cables have extended fire resistant (XFR) properties to IEC 60331-1&2 including water spray according to EN…

  • BFOU(c) 150-250(300)V S4-S8

    Fixed installation for instrumentation, communication, control and alarm systems in both EX (Zone 0, 1 & 2)- and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in NEK TS 606:2009.

  • BFOU(c) 150-250(300)V S4-S8 – Arctic Grade

    Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the OIL & MUD resistance requirement in NEK TS 606:2009. Meets the cold bend / cold impact requirement in CSA 22.2 0.3-01 and IEC…

  • BFOU(i) 150-250(300)V S3-S7

    Fixed installation for instrumentation, communication, control and alarm systems in both EX (Zone 0, 1 & 2)- and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in NEK TS 606:2009.

  • BFOU(i) 150-250(300)V S3-S7 – Arctic Grade

    Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the OIL & MUD resistance requirement in NEK TS 606:2009. Meets the cold bend / cold impact requirement in CSA 22.2 0.3-01 and IEC…

  • BFOV 0.6-1kV

    Fixed installation for power, control and lighting in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Especially resistant to the following hydraulic oils: HydraWay HVXA 46, Nyco Turbonycoil 600, Nyco Turbonycoil 610, Mobil Glygoyle 11 and Turbway 32.

  • BFOV(c)150-250V

    Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Especially resistant to the following hydraulic oils: HydraWay HVXA 46, Nyco Turbonycoil 600, Nyco Turbonycoil 610, Mobil Glygoyle 11 and Turbway 32.

  • BFOV(i) 150-250V

    Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Especially resistant to the following hydraulic oils: HydraWay HVXA 46, Nyco Turbonycoil 600, Nyco Turbonycoil 610, Mobil Glygoyle 11 and Turbway 32.

  • BFSI-EMC 1kV CU Firetuf

    Brannresistent, røyksvak og halogenfri kabel, der det stilles strenge krav til driftssikkerhet under og etter brann (testet i henhold til de strengeste krav til brannresistans). Kan anvendes både innendørs og utendørs om kabelen beskyttes mot direkte sollys. Benyttes i anlegg der kraftforsyningen må fungere under så vel som etter en…

  • BFXI-EX 1kV CU Firetuf

    BFXI-EX 1kV (FIRETUF) Brannresistent, røyksvak og halogenfri kabel, der det stilles strenge krav til driftssikkerhet under og etter brann (testet i henhold til de strengeste krav til brannresistans). Entrådet CL1 (ihht IEC 60228). Kan anvendes både innendørs og utendørs om kabelen beskyttes mot direkte sollys. Benyttes i anlegg der kraftforsyningen…

  • BFXI-FX 1kV CU Firetuf

    BFXI-FX 1kV (Firetuf) Brannresistent, røyksvak og halogenfri kabel, der det stilles strenge krav til driftssikkerhet under og etter brann (testet i henhold til de strengeste krav til brannresistans). Flertrådet ledere (CL2 i hht IEC60228). Kan anvendes både innendørs og utendørs om kabelen beskyttes mot direkte sollys. Benyttes i anlegg der…

  • BI 0,6/1kV

    Unarmoured fire resistant cable for fixed installation in ships where cable protection is required. Control, alarm, power, emergency and critical systems. Can be installed and operated both indoors and outdoors. The cable is dual wall insulated.

  • BI 500V Firetuf

    BI 500V Firetuf. Brannresistent, røyksvak og halogenfri kabel, der det stilles strenge krav til driftssikkerhet under og etter brann (testet i henhold til de strengeste krav til brannresistans). Klasse 1 Entrådet leder. Kan anvendes både innendørs og utendørs om kabelen beskyttes mot direkte sollys. Benyttes i anlegg der kraftforsyningen må…

  • BI(c) 250V

    Unarmoured fire resistant cable for fixed installation in ships where cable protection is not required. Recommended for instrumentation, communication, control, alarm, emergency and critical systems. Can be installed and operated both indoors and outdoors.

  • BI(i) 250V

    Unarmoured fire resistant cable for fixed installation in ships where cable protection is not required. Recommended for instrumentation, communication, control, alarm, emergency and critical systems. Can be installed and operated both indoors and outdoors.

  • BostDrive™ Service Loops

    Draka service loops are offered in a variety of forms, generally considered as “Good”, “Better”, and “Best” designs in order to accommodate a broad spectrum of customer requirements.

  • BroadCat 6 U/UTP HD Hvit

    Primary (Campus), Secondary (Riser), Tertiary (Horizontal). White colour sheath without print legend for open installations. IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; IEEE 802.5 16 MB; ISDN; TPDDI; ATM

  • BroadCat5 U/UTP Hvit

    Generic cabling systems. White colour sheath without print legend for open installations.

  • BU 0.6-1(1.2)kV P17

    Fixed installation for power, control and lighting in safe areas, emergency and critical systems where requirement for fire resistance exists. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009. These cables are double-insulated and Single core cables are used as…

  • BU(c) 150-250(300)V S14

    Fixed installation for instrumentation, communication, control and alarm systems in both EX-(Zone 2) and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in NEK TS 606:2009.

  • BU(i) 150-250(300)V S13

    Fixed installation for instrumentation, communication, control and alarm systems in both EX-(Zone 2) and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in NEK TS 606:2009.

  • BUS CABLE KNX-EIB LSFR0H

    Halogenfri kobberkabel beregnet for innendørs installasjoner av KNX / EIB (European Installation Bus) system. Kabelen er egnet for installasjon i kanaler, kabelbroer, stiger og under datagulv. Rundt kabelkjernen er det båndert med et aluminiumsbånd som gir god skjerming mot ytre støy. Fortinnet jordtråd og rivetråd er innlagt for enkel installasjon.…

  • BUS kabel EIB-KNX

    Kobberkabel beregnet for innendørs installasjoner av KNX / EIB (European Installation Bus) system. Kabelen er egnet for installasjon i kanaler, kabelbroer, stiger og under datagulv. Rundt kabelkjernen er det båndert med et aluminiumsbånd som gir god skjerming mot ytre støy. Fortinnet jordtråd og rivetråd er innlagt for enkel installasjon. Ytterkappen…

  • BXOI 0,6/1kV

    Armoured fire resistant cable for fixed installation in ships where cable protection is required. Control, alarm, power, emergency and critical systems. Can be installed and operated both indoors and outdoors.

  • BXOI 250V

    Armoured fire resistant cable for fixed installation in ships where cable protection is required. Recommended for instrumentation, communication, control, alarm, emergency and critical systems. Can be installed and operated both indoors and outdoors.

  • BXOI(i) 250V

    Armoured fire resistant cable for fixed installation in offshore installations where cable protection is required. Recommended for instrumentation, communication, control, alarm, emergency and critical systems. Can be installed and operated both indoors and outdoors.

  • Cat 3 F/UTP 25/50/100 par

    These cables are used as riser cable in structured cabling networks, most often between distribution frames.

  • Cat.7 S/FTP – Patch

    Work area and patch cord cable IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T IEEE 802.5 16 MB; ISDN; TPDDI; ATM

  • Cat5e F/UTP

    Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; IEEE 802.5 16 MB; ISDN; TPDDI; ATM Power over Ethernet (PoE) / PoE+

  • Cat5e SF/UTP

    Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; IEEE 802.5 16 MB; ISDN; TPDDI; ATM Power over Ethernet (PoE) / PoE+

  • Cat5e SF/UTP – Patch

    Work area and patch cord cable IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; IEEE 802.5 16 MB; ISDN; TPDDI; ATM

  • Cat5e U/UTP

    Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; IEEE 802.5 16 MB; ISDN; TPDDI; ATM Power over Ethernet (PoE) / PoE+.

  • Cat5e U/UTP – Patch

    Work area and patch cord cable IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; IEEE 802.5 16 MB; ISDN; TPDDI; ATM

  • Cat6 U/FTP

    Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T IEEE 802.5 16 MB; ISDN; TPDDI; ATM Power over Ethernet (PoE) / PoE+

  • Cat6 U/UTP HD

    Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; IEEE 802.5 16 MB; ISDN; TPDDI; ATM

  • Cat6 U/UTP – Patch

    Work area and patch cord cable IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; IEEE 802.5 16 MB; ISDN; TPDDI; ATM

  • Cat6a F/FTP

    Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T IEEE 802.5 16 MB; ISDN; FDDI; ATM

  • Cat6a S/FTP

  • Cat6a U/FTP

    Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T IEEE 802.5 16 MB; ISDN; FDDI; ATM Power over Ethernet (PoE) / PoE+

  • Cat7 S/FTP

    Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T IEEE 802.5 16 MB; ISDN; TPDDI; ATM

  • Cat7A S/FTP UC1200

    Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T, 100Base-T, 1000Base-T, 10GBase-T; IEEE 802.5 ISDN, TPDDI, ATM, CATV, Broadband Video

  • Cat7A S/FTP UC1500

    Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T, 100Base-T, 1000Base-T, 10GBase-T; IEEE 802.5 ISDN, TPDDI, ATM, CATV, Broadband Video, SOHO-Cabling Power over Ethernet (PoE) / PoE+

  • CONTROL CABLE 0.6/1kV 12 & 10 AWG armored and sheathed

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for marine vessels, offshore and land drilling rigs, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • CONTROL CABLE 0.6/1kV 12 & 10 AWG UNARMORED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • CONTROL CABLE 0.6/1kV 14 AWG ARMORED AND SHEATHED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore, land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for…

  • CONTROL CABLE 0.6/1kV 14 AWG UNARMORED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • CONTROL CABLE 0.6/1kV 16 AWG ARMORED AND SHEATHED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore, land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for…

  • CONTROL CABLE 0.6/1kV 16 AWG UNARMORED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • CONTROL CABLE 0.6/1kV 18 AWG ARMORED AND SHEATHED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1,…

  • CONTROL CABLE 0.6/1kV 18 AWG UNARMORED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • Drop 1.0/4.6

    Drop cables are used in private and commercial TV signal distribution networks and as antenna cable for terrestrial and satellite broadcast systems. This predestined headend cable is manufactured with vacuum technology. The cable layers thereby have high friction forces which allow automatic dismantling also at small lengths.

  • Drum Buddy

  • EFSP 3kV Airport

    Spesialkabel til flyplassbelysning. Tillatt forlagt innendørs, utendørs og i jord uten ekstra beskyttelse. Tilfredsstiller kravene til Luftfartsverkets hovedorganisasjon.

  • EFSP 3kV Airport

    Spesialkabel til flyplassbelysning. Tillatt forlagt innendørs, utendørs og i jord uten ekstra beskyttelse. Tilfredsstiller kravene til Luftfartsverkets hovedorganisasjon.

  • EX 1kV AL

    Fordelingsanlegg inntil 1kV. Tillatt også som krysningsledning og stikkledning. REN-publikasjon beskriver bygging og drift.

  • EXXP

    Lett signalkabel for brannmeldeanlegg o.l., hvor det ikke kreves skjerm. Tillatt innendørs.

  • FEBI 750V Draka 1,5-2,5

    Jordkabel for bruk i signalanlegg, langs jernbane o.l. Kabelen er bygget etter Jernbaneverkets spesifikasjoner og kan forlegges i jord uten ekstra beskyttelse eller installeres innendørs. Kablene er fettfylte for å forhindre vanninntrengning. Gnagerbeskyttet

  • FEBI 750V Draka 4-25

    Jordkabel for bruk i signalanlegg, langs jernbane o.l. Kabelen er bygget etter Jernbaneverkets spesifikasjoner og kan forlegges i jord uten ekstra beskyttelse eller installeres innendørs. Kablene er fettfylte for å forhindre vanninntrengning. Gnagerbeskyttet

  • Flextreme H07RN-F

  • H07RN-F

    DRAKAFLEX forsterket, oljebestandig gummikabel for bruk innendørs, utendørs og ombord i skip hvor bevegelig gummikabel er tillatt. Oppfyller kravene til NSHO/NMHVO, har gode kuldeegenskaper og er motstandsdyktig mot fuktighet. Eksempel: Til flyttbare motorer, apparater, kraner, maskiner, skjøtekabel, samt flytebrygger og oppdrettsanlegg når kabelen gis mekanisk beskyttelse.

  • HD PRO 0.6/2.8 AF

  • HD PRO 1.0/4.8 AF

  • IFLI 250V

    Signalkabel for brannmeldeanlegg o.l. Oppfyller overføringskravene ved elektroniske sentraler. Tillatt innendørs og utendørs. Halogenfrie kabler anbefales brukt når det er viktig å unngå dannelse av tett røyk og korrosive gasser i tilfelle en overoppheting eller brann.

  • IFLI 250V P16

    Signalkabel for brannmeldeanlegg o.l. Oppfyller overføringskravene ved elektroniske sentraler. Tillatt innendørs og utendørs. Halogenfrie kabler anbefales brukt når det er viktig å unngå dannelse av tett røyk og korrosive gasser i tilfelle en overoppheting eller brann.

  • IFLI 250V P16

    Signalkabel for brannmeldeanlegg o.l. Oppfyller overføringskravene ved elektroniske sentraler. Tillatt innendørs og utendørs. Halogenfrie kabler anbefales brukt når det er viktig å unngå dannelse av tett røyk og korrosive gasser i tilfelle en overoppheting eller brann.

  • IFLI 500V

    Faste installasjoner i åpne anlegg. Tillatt innendørs og utendørs. Halogenfri kabel som anbefales brukt når det er viktig å unngå dannelse av tett røyk og korrosive gasser i tilfelle en overoppheting eller brann. Snurrebass og Snurrebukk er utleggingsutstyr for rørtråd.

  • IFSI 1kV CU m/ AL skjerm

    Kraftkabel med inntil 1 kV driftsspenning. Tillatt innendørs, utendørs og som jordkabel uten ekstra beskyttelse. Kabel har lav koblingsimpedans. Halogenfri kabel anbefales brukt når det er viktig å unngå dannelse av tett røyk og korrosive gasser i tilfelle en overoppheting eller brann. Denne kabel er godt egnet som sjøkabel ned…

  • IFSI-EMC 1kV AL

    Kraftkabel med inntil 1kV driftsspenning. Tillatt innendørs, utendørs og som jordkabel uten ekstra beskyttelse. Cu-skjermen er 100% tett, har lav koblingsimpedans og oppfyller EMC-direktivet. 3-leder kabel er symmetrisk oppbygd. Halogenfri kabel anbefales brukt når det er viktig å unngå dannelse av tett røyk og korrosive gasser i tilfelle en overoppheting eller brann.

  • IFSI-EMC 500V EMC-LINE

    IFSI-EMC EMC-LINE Halogenfri, røyksvak og flammehemmende. For bruk i signalanlegg. Mangetrådet leder klasse 5 ihht IEC60228 Tillatt brukt innendørs, utendørs og som jordkabel. Cu-skjermen er 100% tett, har lav koblingsimpedans og oppfyller EMC-direktivet. Halogenfrie og røyksvake kabler anbefales brukt når det er viktig å unngå dannelse av tett røyk og…

  • IFSI-EMC 750V EMC-LINE

    IFSI-EMC 750V EMC-LINE Halogenfri, røyksvak og flammehemmende. For bruk i signalanlegg. Tillatt brukt innendørs, utendørs og som jordkabel. Cu-skjermen bestående av CU- er 100% tett, har lav koblings-impedans og oppfyller EMC-direktivet. Halogenfrie og røyksvake kabler anbefales brukt når det er viktig å unngå dannelse av tett røyk og korrosive gasser…

  • IFSI-EMC 1kV AL EMC-LINE

    Halogenfri, røyksvak og flammehemmende. Kraftkabel med inntil 1kV driftsspenning. Tillatt innendørs, utendørs og som jordkabel uten ekstra beskyttelse. Cu-skjermen er 100% tett, har lav koblingsimpedans og oppfyller EMC-direktivet. 3-/4-leder kabel er symmetrisk oppbygd. Halogenfri og røyksvak kabel anbefales brukt når det er viktig å unngå dannelse av tett røyk og korrosive gasser i…

  • IFSI-EMC 1kV CU EMC-LINE

    IFSI-EMC (EMC-LINE) Kraftkabel med inntil 1 kV driftsspenning. Tillatt innendørs, utendørs og som jordkabel uten ekstra beskyttelse. Cu-skjermen er 100% tett, har lav koblingsimpedans og oppfyller EMC-direktivet. 3-leder er symmetrisk oppbygd. Halogenfri og røyksvak kabel anbefales brukt når det er viktig å unngå dannelse av tett røyk og korrosive gasser i tilfelle en overoppheting…

  • IFXI-EX 500V

    Halogenfri og flammehemmet kabel. Røykutviklingen ved brann er liten, liten røyktetthet og røyken er ikke skadelig for elektrisk utstyr. Gode avmantlings egenskaper. Egnet til fast forlegning, i rør, kanal, i eller under puss samt opphengt på kabelbroer. Tillatt forlagt innendørs og utendørs. Ikke tillatt nedgravd eller forlagt i vann. UV-bestandig ytterkappe. Fasefargene er UV-beskyttet.

  • IFXI-FX 500V

  • IX 750V

    Ledning for rør-/kanal-anlegg i åpen eller skjult utførelse og som koblingsledning. Halogenfri ledning, som anbefales brukt når det er viktig å unngå dannelse av tett røyk og korrosive gasser, i tilfelle en overoppheting eller brann.

  • JN-TRX 1.8mm

    JETnet: buffered Fiber Optic Cable -dry core

  • JN-URE 3.9mm

    JETnet: buffered Fiber Optic Cable -dry core

  • JN-SM-XS-Line

    JetNet: Stranded Loose Tube Fiber Optic Cable -dry core- single sheath

  • Kat 6 UTP

  • KGF

    Blank glødet kobberline til jordingsapplikasjoner.

  • KGF

    Blank glødet kobberline til jordingsapplikasjoner.

  • KHF

    Blank hardtrukket kobberline til jordingsapplikasjoner.

  • KHF

    Blank hardtrukket kobberline til jordingsapplikasjoner.

  • Koax 10

  • ME

    Solid PE or Foam-skin-PE insulated telephone cables, gel filled, duct/buried outdoor cables

  • METE

    Foam-Skin PE insulated long distance cable, filled and protection against inductive interference, PE outer sheath

  • MEWYE

    Subaqua / Underwater Cable Stainless Steel Tube - Inner PE sheath - Steel Wire Armour with Bitumen - Outer PE sheath

  • MUD RESISTANT POWER CABLE 2000V or 4/0 AWG to 1111 MCM

    Bostrig Type P Mud Resistant Cable is primarily designed for power, control, signal, and instrumentation for marine vessels, and offshore production facilities. Instead of Polychloroprene (Neoprene), they are sheathed in our proprietary elastomeric formulation which is not only mud-resistant but is qualified as a Low-Smoke Zero-Halogen (LSZH) cable in accordance…

  • Multi PN

    Ledning for røranlegg i åpen eller skjult utførelse og som koblingsledning. Gul/rød farge er tillatt for signal referansejord, tele og data (SRJ).

  • MXLE

    Foam-skin-PE insulated telephone cables, gel filled, moisture barrier sheath – duct/buried outdoor cables

  • N00VH-F

    Fleksibel PVC lav volt tvillingledning Til f.eks solcellepanel og høyttalere For innendørs bruk

  • NANO 6-8 mm

    Utendørs mikro kanalkabel Slitesterk PE-kappe Løs kledning 12 – 144 fiber Metallfri og halogenfri

  • P-Laser

    P-Laser is the first eco-sustainable cable for electrical grids. It gives you the ideal solution with which to deliver enhanced network reliability, whilst enjoying operational and environmental benefits.

  • PF-PS-K

    PF-PS-K til bruk i fast eller bevegelig opplegg innendørs. Instrumentering og prosess-styring for overføring av digitale og analoge signaler, telefoni, varslingsanlegg. Lederene er PVC isolert og kabelen har en felles flettet fortinnet cu-skjerm og jordtråd. Parene er nummererte for identifikasjon og lederfarge hvit og blå. Kabelen er godkjent for bruk…

  • PFK

    Fleksibel signalkabel for innendørsbruk. Bruksområde instrumentering og prosesskontroll med både digitale og analoge signaler. Kabelen er også egnet for høytalere, signalering og kontroll systemer i radio og TV studio. De mangetrådete lederne er fortinnet, isolert med PVC og snodd under felles kappe av PVC. Lederne er fargekodet etter standard DEF 61-12 for enkel identifikasjon.

  • PFLP 250V

    Signalkabel for brannmeldeanlegg o.l. Oppfyller kravene ved elektroniske sentraler. Tillatt innendørs og utendørs.

  • PFSK

    Fleksibel skjermet signalkabel for innendørsbruk. Bruksområde er instrumentering og prosess-kontroll med både digitale og analoge signaler. Kabelen er også egnet for høytalere, signalering og kontroll systemer i radio og TV studio. De mangetrådete lederne er fortinnet, isolert og snodd under felles flettet kobberskjerm og kappe av PVC. Lederne er fargekodet etter standard DEF 61-12 for enkel identifikasjon.

  • PFSP 1kV Airport

    Spesialkabel til flyplassbelysning. Tillatt forlagt innendørs, utendørs og i jord uten ekstra beskyttelse. Tilfredstiller kravene til Luftfartsverkets hovedorganisasjon.

  • PFSP 1kV Airport

    Spesialkabel til flyplassbelysning. Tillatt forlagt innendørs, utendørs og i jord uten ekstra beskyttelse. Tilfredsstiller kravene til Luftfartsverkets hovedorganisasjon.

  • PFSP 1kV AL

    Kraftkabel med inntil 1 kV driftspenning. Tillatt innendørs, utendørs og som jordkabel uten ekstra beskyttelse.

  • PFSP 1kV CU

    Kraftkabel med inntil 1 kV driftspenning. Tillatt innendørs, utendørs og som jordkabel uten ekstra beskyttelse. 1,5mm² & 2,5mm² leveres med aluminiumsfolie og uisolert bileder eller med konsentrisk skjerm. Klasse 1 entrådet leder >4mm² har konsentrisk CU skjerm og klasse 2 flertrådet leder.

  • PFSP 6kV Airport

    Spesialkabel til flyplassbelysning. Primærkabel til banebelysning. Tillatt forlagt innendørs, utendørs og i jord uten ekstra beskyttelse. Produktet oppfyller norske klimakrav.

  • PFSP 500V

    For bruk I signalanlegg. Tillatt brukt innendørs og utendørs. Hver firer har fortsettende nummerering. Leder nr.1 og 2 kobles til par, leder nr.3 og 4 kobles til par osv.

  • PFSP 750V

    For bruk i signalanlegg. Tillatt brukt innendørs, utendørs og som jordkabel.

  • PFSP-EMC 5kV Airport

    Spesialkabel til flyplassbelysning. Primærkabel til banebelysning. Tillatt forlagt innendørs, utendørs og i jord uten ekstra beskyttelse.Cu-skjermen er 100 % tett, har lav koblingsimpedans og oppfyller EMC-direktivet. Produktet oppfyller krav til norske normer.

  • PFSP-EMC 5kV Airport

    Spesialkabel til flyplassbelysning. Primærkabel til banebelysning. Tillatt forlagt innendørs, utendørs og i jord uten ekstra beskyttelse. Cu-skjermen er 100 % tett, har lav koblingsimpeldans og oppfyller EMC-direktivet.

  • PFXP 1kV AL

    Dobbeltisolert kabel for faste installasjoner i åpne anlegg, røranlegg og kanaler. Tillatt innendørs, utendørs og i jord hvis den gis ekstra beskyttelse.

  • PFXP 1kV CU

    Dobbeltisolert kabel for faste installasjoner i åpne anlegg, røranlegg og kanaler. Tillatt innendørs, utendørs og i jord hvis den gis ekstra beskyttelse.

  • PFXP 500V

    Dobbeltisolert kabel for fast forlegning, i rør, kanal, i eller under murpuss, kabelstige eller opphengt i wire. Kan benyttes innendørs og utendørs, dog ikke forlagt i bakken eller i vann. UV-beskyttet for utendørs bruk. Lederisolasjonen skal beskyttes mot direkte UV-lys som kan fremkomme ved for eksempel tilkobling i belysningsarmaturer eller…

  • PHFX-A 1kV

    Power and control cable for fixed installations. Good mechanical and electrical protection. Designed to fulfill the requirements for cabling on ships.

  • PHFX-A 1kV Class 5

    Power and control cable for fixed installations. Good mechanical and electrical protection. Designed to fulfill the requirements for cabling on ships.

  • PHFX-A 3kV EMC

    Power and control cable for fixed installations. Good mechanical and electrical protection. Designed to fulfill the requirements for cabling on ships.

  • PHFX-AFR 1kV

    Power and control cable for fixed installations. Designed to maintain operation during fire and to fulfill the requirements for cabling in ships. Used for safety, alarm and other critical systems.

  • PHFX-U 1kV

    Power and control cable for fixed installations. Designed to fulfill the requirements for cabling on ships.

  • PHFX-U 1kV Class 5

    Power and control cable for fixed installations. Designed to fulfill the requirements for cabling on ships.

  • PHFX-UFR 1kV

    Power and control cable for fixed installations. Designed to maintain operation during fire and to fulfill the requirements for cabling in ships. Used for safety, alarm and other critical systems.

  • PL

    Bevegelig plastkabel for flyttbare lamper og apparater i tørre rom.

  • PMH

    Bevegelig plastkabel for flyttbare ovner, vaskemaskiner o.l. innendørs. PMH er tillatt ombord i skip i innredning og likeverdige rom.

  • PN 750V

    Ledning for røranlegg i åpen eller skjult utførelse og som koblingsledning. Gul/rød farge er tillatt for signal referansejord, tele og data (SRJ).

  • POWER CABLE 0.6/1kV & 2000V, 18 AWG to 1111 MCM UNARMORED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • POWER CABLE 0.6/1kV & 2000V, 8 AWG to 1111 MCM ARMORED AND SHEATHED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • POWER CABLE 0.6/1kV, 8 AWG to 4/0 AWG ARMORED AND SHEATHED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • POWER CABLE 0.6/1kV, 8 AWG to 4/0 AWG UNARMORED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • POWER CABLE 0.6/1kV, 8 AWG to 777 MCM ARMORED AND SHEATHED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • POWER CABLE 0.6/1kV, 8 AWG to 777 MCM ARMORED AND SHEATHED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • POWER CABLE 0.6/1kV, 8 AWG to 777 MCM ARMORED AND SHEATHED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • POWER CABLE 0.6/1kV, 8 AWG to 777 MCM UNARMORED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • POWER CABLE 0.6/1kV, 8 AWG to 777 MCM UNARMORED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • POWER CABLE 0.6/1kV, 8 AWG to 777 MCM UNARMORED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • VFD POWER CABLE 2000V UNARMORED OR ARMORED AND SHEATHED

    Bostrig™ Type P shielded three conductor VFD Marine and Offshore Cable is designed specifically for use with variable frequency AC motor drives. This cable is designed to significantly mitigate the deleterious effects of high frequency harmonics and electromagnetic interference (EMI) on the motor /drive system as well as the adjacent…

  • PROFIBUS

  • PROFIT

    Ferdig trukket ledning/kabel i korrugert rør. Leveres som 16mm rør eller 20mm rør avhengig av antall ledere/kabel, se bestillingsinformasjon. Det ferdigtrukkede røret kan pusses eller støpes inn i betong, og installeres i alle bygningskonstruksjoner. Ekstra god mekanisk styrke og kuldeegenskaper, kan forlegges ved –25°C. Røret og ledning/kabel er selvslukkende ved…

  • PROlight 0,6/1kV

    Halogenfri, flammenhemmende og selvslukkende ved brann. Røkutviklingen ved brann er liten og har lav røyktetthet (gjør evakuering lettere) og er ikke skadelig for elektrisk utstyr. Åpen fast forlegning, innendørs og utendørs, i rør og i bakken/vann. Ikke for bruk i eksplosjonsfarlige rom. Kan nedpløyes. UV-bestandig. Forsiktighet utvises ved forlegning under…

  • PROlight 0,6/1kV

    Halogenfri, flammenhemmende og selvslukkende ved brann. Røkutviklingen ved brann er liten og har lav røyktetthet (gjør evakuering lettere) og er ikke skadelig for elektrisk utstyr. Åpen fast forlegning, innendørs og utendørs, i rør og i bakken/vann. Ikke for bruk i eksplosjonsfarlige rom. Kan nedpløyes. UV-bestandig. Forsiktighet utvises ved forlegning under…

  • ProSea 1kV AL

  • PRSuper 500V Lys brun

    Faste installasjoner i åpne anlegg. Tillatt innendørs og utendørs. Spesielt tilpasset for panel og laft. Trekk & Kapp leveringsform er metermerket kabel på snelle, opphengt inne i en eske.

  • PRSuper 500V Wessel

  • PRSuper 500V

    Faste installasjoner i åpne anlegg. Tillatt innendørs og utendørs. Snurrebass og Snurrebukk er utleggingsutstyr for rørtråd. Trekk & Kapp leveringsform er metermerket kabel på snelle, opphengt inne i en eske.

  • PT

  • PT-HF

    Uskjermet halogenfri selvslukkende signal- og alarmkabel. Benyttes i alle typer svakstrøms anlegg som; hustelefonanlegg, brann- og tyverianlegg, ringeanlegg, calling- og signal-anlegg. For innendørs fast montering. Fargekode CN-1. Farge hvit, RAL 9010.

  • PT-S

  • PTS-HF

    Skjermet halogenfri flammehemmet signal- og alarmkabel. Benyttes i alle typer svakstrøms anlegg som; hustelefonanlegg, brann- og tyverianlegg, ringeanlegg, calling- og signal-anlegg. For innendørs fast montering. Fargekode CN-1. Kabelen har en felles AI-folieskjerm, fortinnet jordtråd og brannhemmende og halogenfri ytterkappe med farge hvit, RAL 9010.

  • PVXP 250V

    Signalkabel for brannmeldeanlegg o.l. Oppfyller overføringskravene ved relestyrte sentraler. Tillatt innendørs og utendørs.

  • PXXP 250V

    Signalkabel for brannmeldeanlegg o.l. Oppfyller kravene ved elektroniske sentraler. Tillatt innendørs og utendørs.

  • QANE

    1000 N armoured central tube cable w. 2 – 24 fibres, glass yarns, steel armouring and PE sheath. VDE: A-DQ(ZN)(SR)2Y

  • QENE

    Stranded loose tube cable with up to 312 fibres for direct burial. Inner PE sheath, corrugated steel tape armouring and outer PE sheath. VDE: A-DQ2Y(SR)2Y

  • QERE-R1,6

  • QERE-R3,4

  • QEVE-R2,6/R2,6

  • QFCI

    Optical cable for indoor and outdoor use in vital communication and emergency systems that need to be operational during fire. The cable has a patented design that ensures operation for more than 3 hours in fires up to 1000ºC. The cable is halogen free and flame retardant to protect against…

  • QFCI MUD

    Optical cable for indoor and outdoor use in vital communication and emergency systems that need to be operational during fire. The cable has a patented design that ensures operation for more than 3 hours in fires up to 1000ºC. The cable is halogen free and flame retardant to protect against…

  • QWPK H07BQ-F PUR

    Halogenfri fleksibel vær og olje bestandig kabel, spesielt anvendelig der kabelen utsettes for mekanisk påkjenning. Kan benyttes i tørre, fuktige eller våte miljøer, f.eks. i industrielle anlegg, jordbruksanlegg og i varmeinstallasjoner forutsatt at det ikke er risiko for kontakt med varme deler eller stråling. Kan benyttes som tilførsel til elektrisk…

  • QXAI-I/O

    Kanalkabel utendørs og innendørs Halogenfri og flammehemmende Løs kledning 12 – 144 fiber Gnagebeskyttet med glassgarn

  • QXWE D90 CDS-3677

  • QXWE-FRP 7mm

    Optical fibre cables for aerial installation.

  • QXWE-FRP 9mm

  • QXWE-W0.7

    Optical fibre cables for drop aerial installation.

  • QXWE-W1.4

    Optical fibre cables for aerial installation.

  • QXXE

    Utendørs kanalkabel Slitesterk PE-kappe Løs kledning 12 – 576 fiber Metallfri og halogenfri

  • QXXI-LSHF – Grønn

    Kanalkabel utendørs og innendørs Halogenfri og flammehemmende Løs kledning 12 – 96 fiber Langsgående vanntett Grønn ytterkappe

  • QXXI-I/O- Gul

    Stamkabel utendørs og innendørs Halogenfri og flammehemmende Løs kledning 12 – 144 fiber Langsgående vanntett Gul ytterkappe

  • RFA 1/2”

  • RFA 7/8”

  • RFF 1/2”

  • RFOU 0.6-1(1.2)kV P1-P8

    Fixed installation for power,control and lighting in both EX (Zone 0, 1 & 2)- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009.

  • RFOU 0.6-1(1.2)kV P1-P8 – Arctic Grade

    Fixed installation for power,control and lighting in both EXand safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the OIL & MUD resistance requirement in NEK 606. Meets the cold bend / cold impact requirement in CSA 22.2 0.3-01 and IEC 60092-350 clause 8.10…

  • RFOU 12-20(24)kV P19-P21

    Fixed installation for medium voltage (MV) power in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009

  • RFOU 18-30(36)kV P20-P22

    Fixed installation for medium voltage (MV) power in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids.

  • RFOU 3.6-6(7.2)kV P2-P9

    Fixed installation for medium voltage (MV) power in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids.

  • RFOU 6-10(12)kV P3-P10

    Fixed installation for medium voltage (MV) power in both EXand safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009

  • RFOU 6/10(12)kV P3/P10

    Fixed installation for medium voltage (MV) power in both EXand safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009

  • RFOU 8.7-15(17.5)kV P4-P11

    Fixed installation for medium voltage (MV) power in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009

  • RFOU-HCF 18-30(36)kV P33 – Hydrocarbon Fire

    Fixed installation for medium voltage (MV) power in both EX- and safe areas, emergency and critical systems where requirement for fire resistance is vital.

  • RFOU-HCF 6-10(12)kV P30 – Hydrocarbon Fire

    Fixed installation for medium voltage (MV) power in both EX- and safe areas, emergency and critical systems where requirement for fire resistance is vital.

  • RFOU-HCF 8.7-15(17.5)kV P31 – Hydrocarbon Fire

    Fixed installation for medium voltage (MV) power in both EX- and safe areas, emergency and critical systems where requirement for fire resistance is vital.

  • RFOU-VFD 0.6-1(1.8-3)kV – Class 2 – Variable Frequency Drives

    Special cable for Variable Frequency Drives / Azimuth motors up to 1kV. Suitable for voltage peaks up to 3600V. Armoured cable for fixed installations in ships and offshore units. Can be installed and operated both indoors and outdoors. Oil and MUD resistant to NEK606.

  • RFOU-VFD 0.6-1(1.8-3)kV – Class 5 – Variable Frequency Drives

  • RFOU(c) 150-250(300)V S2-S6

    Fixed installation for instrumentation, communication, Control and alarm systems in both EX (Zone 0, 1 & 2)- and safe areas. Meets the mud resistant requirements in NEK TS 606:2009.

  • RFOU(c) 150-250(300)V S2-S6 – Arctic Grade

    Fixed installation for instrumentation, communication, Control and alarm systems in both EX- and safe areas. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the OIL & MUD resistance requirement in NEK TS 606:2009. Meets the cold bend / cold impact requirement in CSA 22.2 0.3-01 and IEC…

  • RFOU(i) 150-250(300)V S1-S5 – Arctic Grade

    Fixed installation for instrumentation, communication, Control and alarm systems in both EX- and safe areas. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the OIL & MUD resistance requirement in NEK TS 606:2009. Meets the cold bend / cold impact requirement in CSA 22.2 0.3-01 and IEC…

  • RFOU(i) 150-250(300)V S1-S5

    Fixed installation for instrumentation, communication, Control and alarm systems in both EX (Zone 0, 1 & 2)- and safe areas. Meets the mud resistant requirements in NEK TS 606:2009

  • RFX 1/2”

  • RFX 7/8”

  • RG-11

  • RG-213

  • RG-214

  • RG-223

  • RG-58

  • RG-59

  • RQ 750V

    Ledning for røranlegg i åpen eller skjult utførelse og som koblingsledning. Halogenfri ledning, som anbefales brukt når det er viktig å unngå dannelse av tett røyk og korrosive gasser, i tilfelle en overoppheting eller brann.

  • RU 0.6-1(1.2)kV P18

    Fixed installation for power,control and lighting in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the OIL & MUD resistance requirement in NEK TS 606:2009. These cables are double-insulated and Single core cables are used as battery cables.

  • RU(c) 150-250(300)V S12

    Fixed installation for instrumentation, communication, Control and alarm systems in both EX- (Zone 2) and safe areas. Meets the mud resistant requirements in NEK TS 606:2009.

  • RU(i) 150-250(300)V S11

    Fixed installation for instrumentation, communication, Control and alarm systems in both EX- (Zone 2) and safe areas. Meets the mud resistant requirements in NEK TS 606:2009.

  • RZ1-K Afumex Easy 1kV

    Dobbeltisolert koblingskabel, for installasjoner utendørs og innendørs. Maksimal tillatt ledertemperatur ved kortslutning er 250 °C. Halogenfri kabel som anbefales brukt når det er viktig å unngå dannelse av tett røyk og korrosive gasser i tilfelle av overoppheting eller brann. Anbefales brukt i telesentraler, nettstasjoner, koblingsanlegg og som batterikabel. Oppfyller kravene til jord- og kortslutningssikker kabel.…

  • S611T MARINE FIBER OPTIC CABLES UNARMORED

    The Draka S611T series of Marine Shipboard unarmored fiber optic cables are designed especially for the harsh environments of commercial marine vessels, offshore oil platforms, drilling rigs, and other similar applications. Draka S611T low smoke/ zero halogen, flame retardant cables offer versatility and ease of installation in a construction suited…

  • S670T ARMORED AND SHEATHED MARINE FIBER OPTIC CABLES

    The Draka S670T series of Marine Shipboard armored fiber optic cables are designed especially for the harsh environments of commercial marine vessels, offshore oil platforms, drilling rigs, and other similar applications. Draka S670T low smoke/zero halogen, flame retardant cables offer versatility and ease of installation in a construction suited for…

  • Super Stripper Secura No 15

    Avmantlings verktøy for alle runde kabler med diameter 8-13mm. Ingen behov for justering av kuttedybde. Fortinnende knivblader. Ekstra blad for langsgående kutt. 6 isolasjons avmantlingskniver. Utstyrt med lommeklype. Egnet for kabeltyper bl.a. PFXP og IFXI 3G1,5 til 5G2,5.

  • SIGNAL CABLE 0.6/ 1kV, 16 & 14 AWG UNARMORED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • SIGNAL CABLE 0.6/1kV, 16 & 14 AWG ARMORED AND SHEATHED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • SIGNAL CABLE 0.6/1kV, 18 & 16 AWG ARMORED AND SHEATHED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • SIGNAL CABLE 0.6/1kV, 18 & 16 AWG UNARMORED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • SIGNAL CABLE 0.6/1kV, 20, 18 & 16 AWG ARMORED AND SHEATHED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • SIGNAL CABLE 0.6/1kV, 20, 18 & 16 AWG UNARMORED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • SIGNAL CABLE 0.6/1kV, 20 & 18 AWG ARMORED AND SHEATHED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • SIGNAL CABLE 0.6/1kV, 20 & 18 AWG UNARMORED

    Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable…

  • Snurrebukk

    For uttrekking av kabel fra PR og PFXP-snelle. PROFIT snurrebukk for uttrekking av PROFIT bunter

  • SuperCat5 U/UTP – Ute

    Generic cabling systems. Outdoor installations. Filled with compound to prevent water penetration.

  • SuperCat6 F-U/UTP Al.folie Ute

    Outdoor installations. Filled with compound to prevent water penetration. Extra rugged due to a dual outer sheath construction. Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; IEEE 802.5 16 MB; ISDN; TPDDI; ATM

  • SuperCat6 U/UTP – Ute

    Outdoor installations. Filled with compound to prevent water penetration. Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; IEEE 802.5 16 MB; ISDN; TPDDI; ATM

  • SuperCat7 S/FTP Ute / Inne

    Indoor- and outdoor installations, filled with compound to prevent water penetration Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T IEEE 802.5 16 MB; ISDN; TPDDI; ATM

  • Tarmo H07BN4-F

    TARMO slitesterk, selvslukkende, vær- og oljebestandig gummikabel for innendørs og utendørs bruk. Kabelen er fleksibel i kulde ned til – 50°C. Oppfyller kravene til NMHVR er halogenfri og har spesielt gode kuldeegenskaper og motstandsdyktig mot fuktighet.

  • TEAN 1 kV

  • TEAN 1kV

    Armert kabel for forlegging i sjø og jord. Forsterket utførelse som tilfredsstiller Kystdirektoratets krav til kabling av fyr og lykter.

  • TECSUN(PV) H1Z2Z2-K

    PRYSMIAN Solar cables TECSUN (PV) H1Z2Z2-K are intended for use in Photovoltaic Power Supply Systems: Indoor and/or outdoor, in industrial and agriculture fields. They are suitable for applications in/at equipment with protective insulation (Protecting Class II), in explosion hazard areas (PRYSMIAN Internal Testing) and may be installed as fixed or…

  • TERE 1kV CU

    Armert kraftkabel med inntil 1 kV driftspenning. Tillatt som jordkabel uten ekstra beskyttelse og forlagt direkte i sjøvann. Forsterket isolasjon, tåler 3kV spenning.

  • TERE 1kV CU

    Armert kraftkabel med inntil 1 kV driftspenning. Tillatt som jordkabel uten ekstra beskyttelse og forlagt direkte i sjøvann. Forsterket isolasjon, tåler 3kV spenning. Kan også leveres med fiber (TERE-O 1kV)

  • TERE-O 1kV CU

    Armert kraftkabel med inntil 1 kV driftspenning. Tillatt som jordkabel uten ekstra beskyttelse og forlagt direkte i sjøvann. Forsterket isolasjon, tåler 3kV spenning. Kan også leveres uten fiber (TERE 1kV CU)

  • TFSP 1kV AL

  • TFXP 1kV

    "Dobbeltisolert" kabel som tillates forlagt uten ekstra beskyttelse, og som inntakskabel til første fordelingsskap i bygning. UV bestandig leder isolasjon. Produktet er ikke tillatt for alminnelig bruk i bygningsinstallasjoner.

  • TFXP Jetnet 1kV

    "Dobbeltisolert" kabel som tillates forlagt uten ekstra beskyttelse, og som inntakskabel til første fordelingsskap i bygning. UV bestandig leder isolasjon. Produktet er ikke tillatt for alminnelig bruk i bygnings-installasjoner. Med 8 mm / 12 mm blåserør til fiberkabel.

  • TFXP JetNet 1kV

    "Dobbeltisolert" kabel som tillates forlagt uten ekstra beskyttelse, og som inntakskabel til første fordelingsskap i bygning. UV bestandig leder isolasjon. Produktet er ikke tillatt for alminnelig bruk i bygnings-installasjoner. Med 8 mm / 12 mm blåserør til fiberkabel.

  • THFX-C 250V

    Instrumentation, telecommunication and control cable for fixed installations. Good mechanical and electrical protection. Designed to fulfill the requirements for cabling on ships.

  • THFX-U(c) 250V

    Instrumentation, telecommunication and control cable for fixed installations. Designed to fulfill the requirements for cabling on ships.

  • TI 0,6/1kV

    Unarmoured cable for fixed installation in ships where cable protection is not required. Control, general power and lighting systems. Can be installed and operated both indoors and outdoors.

  • TI(c) 0,6/1kV

    Unarmoured shielded cable for fixed installation in ships where cable protection is not required. Control cables and small power ables. Can be installed and operated both indoors and outdoors.

  • TI(c) 250V

    Unarmoured shielded cable for fixed installation in ships where cable protection is not required. Suitable for use on instrumentation and communication systems. Can be installed and operated both indoors and outdoors.

  • TI(i) 250V

    Unarmoured shielded cable for fixed installation in ships where cable protection is not required. Suitable for use on instrumentation and communication systems. Can be installed and operated both indoors and outdoors.

  • TN

    Installasjoner i tunneler med inntil 1 kV driftsspenning. Spesielt designet som nødstrømskabel i rør. Kabelen har beskyttelse mot UV-stråling/sollys og har ekstra beskyttelse mot oljer og diesel. Halogenfri kabel anbefales brukt når det er viktig

  • TN 1000

    Installasjoner i tunneler med inntil 1 kV driftsspenning, hvor den elektriske funksjonsevnen skal opprettholdes under brann. Spesielt designet for nødstrømsystemer. Kabelen har beskyttelse mot UV-stråling/sollys og har ekstra beskyttelse mot oljer og diesel. Halogenfri kabel anbefales brukt når det er viktig å unngå dannelse av tett røyk og korrosive gasser…

  • TNL 1000 1kV – Nødstrøm

    Installasjoner i tunneler med inntil 1 kV driftsspenning, hvor den elektriske funksjonsevnen skal opprettholdes under brann. Spesielt designet for nødstrømsystemer. Cu-skjermen er 100% tett og oppfyller EMC-direktivet. Kabelen har beskyttelse mot UV-stråling/sollys og har ekstra beskyttelse mot oljer og diesel. Halogenfri kabel anbefales brukt når det er viktig å unngå…

  • TNL 1kV – Nødstrømskabel i rør

    Installasjoner i tunneler med inntil 1 kV driftsspenning. Spesielt designet som nødstrømskabel i rør. Cu-skjermen er 100% tett og oppfyller EMC-direktivet. Kabelen har beskyttelse mot UV-stråling/sollys og har ekstra beskyttelse mot oljer og diesel. Halogenfri kabel anbefales brukt når det er viktig å unngå dannelse av tett røyk og korrosive…

  • TNL U 1kV – Universal kabel

    Installasjoner i tunneler med inntil 1 kV driftsspenning. Kabelen har beskyttelse mot UVstråling/sollys og har ekstra beskyttelse mot oljer og diesel. Halogenfri kabel anbefales brukt når det er viktig å unngå dannelse av tett røyk og korrosive gasser i tilfelle en overoppheting eller brann.

  • ToughCat5 S/FTP

    Generic Data transmission. This cabel is a Cat5e S/FTP cable meant for use as installation(horizontal) cable in tougher electrical and mechanical environment, including ships and offshore units.

  • ToughCat5 S/FTP + MUD

    Generic Data transmission. This Cat.5e S/FTP cable is based on our DNV and Lloyd Register certified ToughCat, but with an additional fire retardant, halogen-free, low smoke MUD protecting outer jacket. This cabel is meant for use as installation/horisontal cable in tougher electrical and mechanical environment, including ships and offshore units.

  • ToughCat7 S/FTP

    Generic Data transmission. This cable is a Cat7 S/FTP cable meant for use as installation/horizontal cable in tougher electrical and mechanical environment, including ships and offshore units.

  • ToughCat7 S/FTP + MUD

    Generic Data transmission. This cable is a Cat7 S/FTP cable is based on our DNV certified ToughCat, but with an additional fire retardant, halogen-free, low smoke MUD protecting outer jacket. This cabel is meant for use as installation/horisontal cable in tougher electrical and mechanical environment, including ships and offshore units.

  • ToughCat7 Solid Armert S/FTP

    Generic Data transmission. This cable is a Cat7 S/FTP cable meant for use as installation/horizontal cable in tougher electrical and mechanical environment, including ships and offshore units.

  • ToughCat7 Solid + MUD

    Generic Data transmission. This cable is a Cat7 S/FTP cable is based on our DNV certified ToughCat, but with an additional fire retardant, halogen-free, low smoke MUD protecting outer jacket. This cabel is meant for use as installation/horisontal cable in tougher electrical and mechanical environment, including ships and offshore units.

  • ToughCat7 Solid S/FTP

    Generic Data transmission. This cable is a Cat7 S/FTP cable meant for use as installation/horizontal cable in tougher electrical and mechanical environment, including ships and offshore units.

  • TP90

    Bevegelig 90°C dobbeltisolert kabel for innendørs lavspent installasjoner. Eksempel: Halogenlamper, down-light, solcelleanlegg, høytalerkabel.

  • Trunk 3.3/13.5

    CATV cables are used in trunk lines of CATV and broadband networks between headend and subscriber termination point. They are suitable for direct buried and duct laying.

  • TSLE 12/20(24)kV Cu

    Enleder distribusjonskabel, tillatt utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett og kan belastes i henhold til NEN 62.75. Ved innendørs installasjoner skal kablene males med brannhemmende maling eller legges i kanal.

  • TSLF 12kV AL

    Enleder distribusjonskabel, tillatt utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett og kan belastes i henhold til NEN 62.75. Ytre sjikt av halvledende materiale muliggjør elektrisk testing av kappe og detektering av kappeskader. Ved innendørs installasjoner kan kablene males med brannhemmende maling eller legges i kanal.

  • TSLF 12kV CU

    Enleder distribusjonskabel, tillatt utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett og kan belastes i henhold til NEN 62.75. Ytre sjikt av halvledende materiale muliggjør elektrisk testing av kappe og detektering av kappeskader. Ved innendørs installasjoner kan kablene males med brannhemmende maling eller legges i kanal.

  • TSLF 145kV AL

    Enleder distribusjonskabel, tillatt utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett og kan belastes i henhold til NEN 62.75. Ytre sjikt av halvledende materiale muliggjør elektrisk testing av kappe og detektering av kappeskader. Ved innendørs installasjoner kan kablene males med brannhemmende maling eller legges i kanal.

  • TSLF 145kV CU

    Enleder distribusjonskabel, tillatt utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett og kan belastes i henhold til NEN 62.75. Ytre sjikt av halvledende materiale muliggjør elektrisk testing av kappe og detektering av kappeskader. Ved innendørs installasjoner kan kablene males med brannhemmende maling eller legges i kanal.

  • TSLF 170kV AL

    Enleder distribusjonskabel, tillatt utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett og kan belastes i henhold til NEN 62.75. Ytre sjikt av halvledende materiale muliggjør elektrisk testing av kappe og detektering av kappeskader. Ved innendørs installasjoner kan kablene males med brannhemmende maling eller legges i kanal.

  • TSLF 170kV CU

    Enleder distribusjonskabel, tillatt utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett og kan belastes i henhold til NEN 62.75. Ytre sjikt av halvledende materiale muliggjør elektrisk testing av kappe og detektering av kappeskader. Ved innendørs installasjoner kan kablene males med brannhemmende maling eller legges i kanal.

  • TSLF 24kV AL

    Enleder distribusjonskabel, tillatt utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett og kan belastes i henhold til NEN 62.75. Ytre sjikt av halvledende materiale muliggjør elektrisk testing av kappe og detektering av kappeskader. Ved innendørs installasjoner kan kablene males med brannhemmende maling eller legges i kanal.

  • TSLF 24kV CU

    Enleder distribusjonskabel, tillatt utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett og kan belastes i henhold til NEN 62.75. Ytre sjikt av halvledende materiale muliggjør elektrisk testing av kappe og detektering av kappeskader. Ved innendørs installasjoner kan kablene males med brannhemmende maling eller legges i kanal.

  • TSLF 36kV AL

    Enleder distribusjonskabel, tillatt utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett og kan belastes i henhold til NEN 62.75. Ytre sjikt av halvledende materiale muliggjør elektrisk testing av kappe og detektering av kappeskader. Ved innendørs installasjoner kan kablene males med brannhemmende maling eller legges i kanal.

  • TSLF 36kV CU

    Enleder distribusjonskabel, tillatt utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett og kan belastes i henhold til NEN 62.75. Ytre sjikt av halvledende materiale muliggjør elektrisk testing av kappe og detektering av kappeskader. Ved innendørs installasjoner kan kablene males med brannhemmende maling eller legges i kanal.

  • TSLF 72,5kV AL

    Enleder distribusjonskabel, tillatt utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett og kan belastes i henhold til NEN 62.75. Ytre sjikt av halvledende materiale muliggjør elektrisk testing av kappe og detektering av kappeskader. Ved innendørs installasjoner kan kablene males med brannhemmende maling eller legges i kanal.

  • TSLF 72,5kV CU

    Enleder distribusjonskabel, tillatt utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett og kan belastes i henhold til NEN 62.75. Ytre sjikt av halvledende materiale muliggjør elektrisk testing av kappe og detektering av kappeskader. Ved innendørs installasjoner kan kablene males med brannhemmende maling eller legges i kanal.

  • TSLF-J 24kV AL

    3-leder distributionskabel, tillatt utendørs i jord, luft og vann. Snodd med fiberrør og jordline. Kablene er aksielt og radielt vanntett og kan belastes i henhold til NEN 62.75. Ytre sjikt av halvledende material muliggjør elektrisk testing av kappe og detektering av kappeskader. Ved innendørs installasjoner skal kablene males med brannhemmende…

  • TSLF-O 24kV AL

    3-leder distributionskabel, tillatt utendørs i jord, luft og vann. Snodd med fiberrør og jordline. Kablene er aksielt og radielt vanntett og kan belastes i henhold til NEN 62.75.  Ytre sjikt av halvledende material muliggjør elektrisk testing av kappe og detektering av kappeskader. Ved innendørs installasjoner skal kablene males med brannhemmende…

  • TSLF-OJ 24kV AL

    3-leder distributionskabel, tillatt utendørs i jord, luft og vann. Snodd med fiberrør og jordline. Kablene er aksielt og radielt vanntett og kan belastes i henhold til NEN 62.75.  Ytre sjikt av halvledende material muliggjør elektrisk testing av kappe og detektering av kappeskader. Ved innendørs installasjoner skal kablene males med brannhemmende…

  • TSLI 12 kV CU

    Halogenfri og flammehemmende enleder distribusjons-kabel, tillatt innendørs,utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett. Liten røykutvikling ved brann, lav røyktetthet som ikke medfører skader på elektrisk utstyr.

  • TSLI 12 kV AL

    Halogenfri og flammehemmende enleder distribusjons-kabel, tillatt innendørs,utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett. Liten røykutvikling ved brann, lav røyktetthet som ikke medfører skader på elektrisk utstyr.

  • TSLI 145 kV AL

    Halogenfri og flammehemmende enleder distribusjons-kabel, tillatt innendørs,utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett. Liten røykutvikling ved brann, lav røyktetthet som ikke medfører skader på elektrisk utstyr.

  • TSLI 145kV CU

    Halogenfri og flammehemmende enleder distribusjons-kabel, tillatt innendørs,utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett. Liten røykutvikling ved brann, lav røyktetthet som ikke medfører skader på elektrisk utstyr.

  • TSLI 170 kV AL

    Halogenfri og flammehemmende enleder distribusjons-kabel, tillatt innendørs,utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett. Liten røykutvikling ved brann, lav røyktetthet som ikke medfører skader på elektrisk utstyr.

  • TSLI 170kV CU

    Halogenfri og flammehemmende enleder distribusjons-kabel, tillatt innendørs,utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett. Liten røykutvikling ved brann, lav røyktetthet som ikke medfører skader på elektrisk utstyr.

  • TSLI 24 kV CU

    Halogenfri og flammehemmende enleder distribusjons-kabel, tillatt innendørs,utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett. Liten røykutvikling ved brann, lav røyktetthet som ikke medfører skader på elektrisk utstyr.

  • TSLI 24kV AL

    Halogenfri og flammehemmende enleder distribusjons-kabel, tillatt innendørs,utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett. Liten røykutvikling ved brann, lav røyktetthet som ikke medfører skader på elektrisk utstyr.

  • TSLI 36 kV AL

    Halogenfri og flammehemmende enleder distribusjons-kabel, tillatt innendørs,utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett. Liten røykutvikling ved brann, lav røyktetthet som ikke medfører skader på elektrisk utstyr.

  • TSLI 36 kV CU

    Halogenfri og flammehemmende enleder distribusjons-kabel, tillatt innendørs,utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett. Liten røykutvikling ved brann, lav røyktetthet som ikke medfører skader på elektrisk utstyr.

  • TSLI 72,5 kV AL

    Halogenfri og flammehemmende enleder distribusjons-kabel, tillatt innendørs,utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett. Liten røykutvikling ved brann, lav røyktetthet som ikke medfører skader på elektrisk utstyr.

  • TSLI 72,5kV CU

    Halogenfri og flammehemmende enleder distribusjons-kabel, tillatt innendørs,utendørs i jord, luft og vann. Kabelen er aksielt og radielt vanntett. Liten røykutvikling ved brann, lav røyktetthet som ikke medfører skader på elektrisk utstyr.

  • TSRA-FS 24 kV

  • TSRA-FS 24kV

    Treleder kraftkabel med inntil 24 kV driftspenning. For installasjon i sjø, innsjø eller elver. Tillatt som jordkabel uten ekstra beskyttelse. Strømbelastning etter NEN 62.75. Maksimal impulsspenning er 125kV. Konstruksjonen er planlagt for 1-3km lengder. Maksimalt vanndyp 300m.

  • TSRA-FS 36kV

    Treleder kraftkabel med inntil 36 kV driftspenning. For installasjon i sjø, innsjø eller elver. Tillatt som jordkabel uten ekstra beskyttelse. Strømbelastning etter NEN 62.75. Maksimal impulsspenning er 170kV. Konstruksjonen er planlagt for 1-3km lengder. Maksimalt vanndyp 300m.

  • TSRA-IS 24 kV

  • TSRA-IS 24kV

    Treleder kraftkabel med inntil 24 kV driftspenning. For installasjon i sjø, innsjø eller elver. Tillatt som jordkabel uten ekstra beskyttelse. Strømbelastning etter NEN 62.75. Maksimal impulsspenning er 125kV. Konstruksjonen er planlagt for lengder > 3km. Maksimalt vanndyp 300m.

  • TSRA-IS 36kV

    Treleder kraftkabel med inntil 36 kV driftspenning. For installasjon i sjø, innsjø eller elver. Tillatt som jordkabel uten ekstra beskyttelse. Strømbelastning etter NEN 62.75. Maksimal impulsspenning er 170kV. Konstruksjonen er planlagt for 1-3km lengder. Maksimalt vanndyp 300m.

  • TSRA-OWF 36kV

  • TSRA-OWF 36kV

  • TSRE-FS 24kV

    Treleder kraftkabel med inntil 24 kV driftspenning. For installasjon i sjø, innsjø eller elver. Tillatt som jordkabel uten ekstra beskyttelse. Strømbelastning etter NEN 62.75. Maksimal impulsspenning er 125kV Konstruksjonen er planlagt for 1-3km lengder. Maksimalt vanndyp 300m.

  • TSRE-FS 24kV

    Treleder kraftkabel med inntil 24 kV driftspenning. For installasjon i sjø, innsjø eller elver. Tillatt som jordkabel uten ekstra beskyttelse. Strømbelastning etter NEN 62.75. Maksimal impulsspenning er 125kV. Konstruksjonen er planlagt for 1-3km lengder. Maksimalt vanndyp 300m.

  • TSRE-FS 36kV

    Treleder kraftkabel med inntil 36 kV driftspenning. For installasjon i sjø, innsjø eller elver. Tillatt som jordkabel uten ekstra beskyttelse. Strømbelastning etter NEN 62.75. Maksimal impulsspenning er 170kV. Konstruksjonen er planlagt for 1-3km lengder. Maksimalt vanndyp 300m.

  • TSRE-IS 24kV

  • TSRE-IS 24kV

    Treleder kraftkabel med inntil 24 kV driftspenning. For installasjon i sjø, innsjø eller elver. Tillatt som jordkabel uten ekstra beskyttelse. Strømbelastning etter NEN 62.75. Maksimal impulsspenning er 125kV. Konstruksjonen er planlagt for 1-3km lengder. Maksimalt vanndyp 300m.

  • TSRE-IS 36kV

    Treleder kraftkabel med inntil 36 kV driftspenning. For installasjon i sjø, innsjø eller elver. Tillatt som jordkabel uten ekstra beskyttelse. Strømbelastning etter NEN 62.75. Maksimal impulsspenning er 170kV. Konstruksjonen er planlagt for 1-3km lengder. Maksimalt vanndyp 300m.

  • TSVE-IS

    Treleder dobbeltarmert kraftkabel med inntil 24 kV driftspenning. For installasjon i sjø, innsjø eller elver. Tillatt som jordkabel uten ekstra beskyttelse. Strømbelastning etter NEN 62.75. Maksimal impulsspenning er 125kV. Konstruksjonen er planlagt for lengder > 3km. Egnet for vanndyp > 300m.

  • TFXP 1kV AL

    "Dobbeltisolert" kabel som tillates forlagt uten ekstra beskyttelse, og som inntakskabel til første fordelingsskap i bygning. UV bestandig leder isolasjon. Produktet er ikke tillatt for alminnelig bruk i bygnings-installasjoner.

  • TXOI 0,6/1kV

    Armoured cable for fixed installation in ships where cable protection is required. Control, general power and lighting systems. Can be installed and operated both indoors and outdoors.

  • TXOI 250V

    Armoured cable for fixed installation in ships where cable protection is required. Suitable for use on instrumentation and communication systems. Can be installed and operated both indoors and outdoors.

  • TXOI (i) 250V

    Armoured cable for fixed installation in ships where cable protection is required. Suitable for use on instrumentation and communication systems. Can be installed and operated both indoors and outdoors.

  • Universal stripper No. 12

    Universal avmantlings verktøy for alle runde kabler med diameter 8-13mm Ingen behov for justering av kuttedybde. Fortinnende knivblader. Utstyrt med lommeklype. Egnet for kabeltyper bl.a. PFXP og IFXI 3G1,5 til 5G2,5.

  • UX 1000V P15

    Insulated conductor for earthing and bonding services. Mud resistant in accordance with NEK TS 606:2009.

  • W07RRTW-F

    Bevegelig gummikabel godkjent for kontakt med drikkevann. Spesielt egnet for legging direkte i vannkanaler og rør. Beregnet for dybder ned til 350m. Kabelen kan også benyttes i tørre og våte rom, innendørs og utendørs. Maksimal ledertemperatur for kabelen er 90°C.