Specials

  • BFOU H-M 1kV P105

    Fixed installation for power, control and lighting in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Especially resistant to the following hydraulic oils: HydraWay HVXA 46, Nyco Turbonycoil 600, Nyco Turbonycoil 610, Mobil Glygoyle 11 and Turbway 32.   Denne kabelen har skiftet navn fra BFOV 0.6/1kV til BFOU H-M 1kV P105.

  • BFOU M 1kV P105 – Arctic Grade

    Fixed installation for power, control and lighting in both EX (Zone 0, 1 & 2)- and safe areas, emergency and critical systems where requirement for fire resistance exists. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the OIL & MUD resistance requirement in NEK 606. Meets the cold bend / cold impact requirement in CSA 22.2 0.3-01 and IEC 60092-350 Clause 8.10 & Annex E at - 40°C/-35°C.

  • BFOU-HCF (c) 250V S16/S110 – Hydrocarbon Fire

    Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for hydrocarbon fire resistance is vital.

  • BFOU-HCF (i) 250V S15/S109 – Hydrocarbon Fire

    Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for hydrocarbon fire resistance is vital.

  • BFOU-HCF 0.6-1(1.2)kV P34/P118 – Hydrocarbon Fire

    Fixed installation for power, control and lightning in both EX- and safe areas, emergency and critical systems where requirement for fire resistance is vital.

  • BFOU-JF 0.6-1kV – Jet Fire

    Fixed installation for power, control and lightning in both EX- and safe areas, emergency and critical systems where requirement for fire resistance is vital.

  • BFOU-VFD 0.6-1(1.8-3)kV – Class 2 – Variable Frequency Drives

    Special cable for Variable Frequency Drives / Azimuth motors. Suitable for voltage peaks up to 3000V. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009.

  • BFOU-VFD 0.6-1(1.8-3)kV – Class 5 – Variable Frequency Drives

    Special cable for Variable Frequency Drives / Azimuth motors up to 1kV. Suitable for voltage peaks up to 3600V. Armoured cable for fixed installations in ships and offshore units. Can be installed and operated both indoors and outdoors. Oil and MUD resistant to NEK606.

  • BFOU-XFR(c) 150-250(300)V – Extended Fire Resistant

    Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in NEK TS 606:2009. Cables have extended fire resistant (XFR) properties to IEC 60331-1&2 including water spray according to EN 50200 Annex E (90 minutes).

  • BFOU-XFR(i) 150-250(300)V – Extended Fire Resistant

    Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in NEK TS 606:2009. Cables have extended fire resistant (XFR) properties to IEC 60331-1&2 including water spray according to EN 50200 Annex E (90 minutes).

  • BFOU(c) H-M 250V S104

    Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Especially resistant to the following hydraulic oils: HydraWay HVXA 46, Nyco Turbonycoil 600, Nyco Turbonycoil 610, Mobil Glygoyle 11 and Turbway 32.   Denne kabelen har skiftet navn fra BFOV(c) 150/250V til BFOU(c) H-M 250V S104.

  • BFOU(c) M 250V S104 – Arctic Grade

    Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the OIL & MUD resistance requirement in NEK TS 606:2009. Meets the cold bend / cold impact requirement in CSA 22.2 0.3-01 and IEC 60092-350 Clause 8.9 & Annex E at - 40°C/-35°C.

  • BFOU(i) H-M 250V S103

    Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Especially resistant to the following hydraulic oils: HydraWay HVXA 46, Nyco Turbonycoil 600, Nyco Turbonycoil 610, Mobil Glygoyle 11 and Turbway 32.   Denne kabelen har skiftet navn fra BFOV(i) 150/250V til BFOU(i) H-M 250V S103.

  • BFOU(i) M 250V S103 – Arctic Grade

    Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the OIL & MUD resistance requirement in NEK TS 606:2009. Meets the cold bend / cold impact requirement in CSA 22.2 0.3-01 and IEC 60092-350 Clause 8.9 & Annex E at - 40°C/-35°C.

  • RFOU M 1kV P101 – Arctic Grade

    Fixed installation for power,control and lighting in both EXand safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the OIL & MUD resistance requirement in NEK 606. Meets the cold bend / cold impact requirement in CSA 22.2 0.3-01 and IEC 60092-350 clause 8.10 & Annex E at -40°C / -35°C.

  • RFOU-FR 6/10(12)kV P121 Fire Resistant MV cable

    Fixed installation for medium voltage (MV) power in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2016.

  • RFOU-HCF 18-30(36)kV P33 – Hydrocarbon Fire

    Fixed installation for medium voltage (MV) power in both EX- and safe areas, emergency and critical systems where requirement for fire resistance is vital.

  • RFOU-HCF 6-10(12)kV P30/P114 – Hydrocarbon Fire

    Fixed installation for medium voltage (MV) power in both EX- and safe areas, emergency and critical systems where requirement for fire resistance is vital.

  • RFOU-HCF 8.7-15(17.5)kV P31/P115 – Hydrocarbon Fire

    Fixed installation for medium voltage (MV) power in both EX- and safe areas, emergency and critical systems where requirement for fire resistance is vital.

  • RFOU-VFD 0.6-1(1.8-3)kV – Class 2 – Variable Frequency Drives

    Special cable for Variable Frequency Drives / Azimuth motors up to 1kV. Suitable for voltage peaks up to 3600V. Armoured cable for fixed installations in ships and offshore units. Can be installed and operated both indoors and outdoors. Oil and MUD resistant to NEK606.

  • RFOU(c) M 250V S102 – Arctic Grade

    Fixed installation for instrumentation, communication, Control and alarm systems in both EX- and safe areas. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the OIL & MUD resistance requirement in NEK TS 606:2009. Meets the cold bend / cold impact requirement in CSA 22.2 0.3-01 and IEC 60092-350 Clause 8.10 & Annex E at -40°C / -35°C.

  • RFOU(i) M 250V S101 – Arctic Grade

    Fixed installation for instrumentation, communication, Control and alarm systems in both EX- and safe areas. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the OIL & MUD resistance requirement in NEK TS 606:2009. Meets the cold bend / cold impact requirement in CSA 22.2 0.3-01 and IEC 60092-350 Clause 8.10 & Annex E at -40°C / -35°C.